Description: 

The Buckaroos Model 4300E insulated saddle is designed primarily for indoor use on cold and hot service. It can be used outdoors if weather protected. Meets MSS SP-58, 9.2.2 for Type 40 Shields.

Features / Benefits:

  • A complete composite assembly, for Fast and Easy Installation.
  • A 360-degree section of polyisocyanurate pipe insulation for greater Thermal Efficiency and compressive strength. With a 4.0 PCF bottom support-section and a 3.0 PCF top section.
  • A 6 mil thickness, .01 perm rated industrial grade vapor retarder film for Superior Condensation Control.
  • A G-90 galvanized steel Buckaroo 180-degree bottom shield (a 360-degree self-clamping shield also available) for Maximum Insulation Protection at hanger locations.
  • A lock-joint to Reduce Heat Gain/Loss along the longitudinal seams to Save Energy.*

The Model 4300E (Extended Insulation) has the insulation extended beyond the saddle for easy application of a tape butt-strip. Always install the specified insulation thickness to insure system performance.

4300E (Extended) Insulated Saddle

Saves Energy! Saves Labor! Saves Money!

*Lock Joint feature not available on all sizes.

Intended Application:

For indoor use on refrigeration lines, chilled water lines, cold-process piping and thermal-cyclic systems. Use on cold systems where control of condensation is a critical requirement. Use on hot systems up to 300 degrees F to standardize saddle specification. Ideal for domestic hot water and low-pressure (50# max. pressure) steam lines. The Model 4300E insulated saddle saves energy. Insure complete system integrity by eliminating compromised thermal performance at all hanger and support locations. Due to its complete design, the Model 4300E insulated saddle saves labor because it can be installed rapidly by any qualified contractor. The Model 4300E insulated saddle is always a wise investment!

Technical Data:

Physical Property

Value/Unit

Specification Compliance

Insulation density:  (Lbs/Cu. Ft.)

4.0 Lbs Bottom / 3.0 Lbs Top

       ASTM D1622

Thermal Conductivity:

 

 

 

@ 75 degrees F

       .19 btu.in/hr.ft.sq.deg F

       ASTM C518

Service Temperatures

       -297 F to +300 F

       Manufacturer Design Limits

Compressive Resistance

        80 P.S.I.

       ASTM D1621

Water Absorption,

 

 

         Max % by volume:

       .5%

       ASTM C272

Shrinkage,  Max %:

       .2%

       ASTM D2126

Vapor Retarder Film:

 

 

Thickness Average

        6 mil

       ASTM D374

Perm rating

       .010

       ASTM E96 – 93 UBC

4300E Standard Product Dimensions:

Nominal Pipe Size

Insulation Length

Saddle Length

Saddle Gauge

  .5” –  1.5”

9 inches

6 inches

22 Ga.

2” –  5”

18 inches

12 inches

18 Ga.

  6” –  10”

18 inches

14 inches

16 Ga.

12” –  18”

18 inches

14 inches

14 Ga.

20” –  24”

18 inches

14 inches

12 Ga.